Jiangyin M&C Heat Parts Co.,Ltd

Provide Professional Thermal Energy Solutions

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Plate Heat Exchanger Gaskets /

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

Contact Now
Jiangyin M&C Heat Parts Co.,Ltd
Visit Website
City:wuxi
Province/State:jiangsu
Country/Region:china
Contact Person:MrsLi.C
Contact Now

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

Ask Latest Price
Video Channel
Brand Name :M&C
Model Number :NT50M
Certification :SGS FDA ISO
Place of Origin :Jiangsu China (mainland)
MOQ :Negotiation
Price :Negotiation
Payment Terms :L/C, T/T, Western Union
Supply Ability :50000Pcs/Month
Delivery Time :5-8 working days
Packaging Details :Standard export carton /wooden case
Model :NT50M
Name :Plate Heat Exchanger Gasket/Plate
Max Design Pressure :2.5 MPaG Max.
Plate Material :Stainless Steel, Titanium, High Nickel Alloy, Nickel and others
Gasket Material :NBR, EPDM, FPM, NBRHT, VITON
Surface Area :0.18㎡
Plate Theta Angle :129° 127°
Connection Dia :56 mm
Plate Corrugate Thickness :2.8 mm
Plate Centre Length* Width :743*130 mm
Plate Shape Length*Width :864*246 mm
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

NT50M AISI316L 0.5mm NBR Plates and Gaskets For GEA Plate Heat Exchanger

Plate Heat Exchanger Introduction

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

No. Component No. Component
1 Top beam 6 HE plates
2 Piping connections 7 Bottom guide beam
3 Fixed plate 8 HE plate gasket
4 Column 9 Nut on tensioning bolt
5 Loose plate 10 Tensioning bolts

Serially arranged profiled HE plates with flow openings form a pack of flow gaps inside the PHE. The flow media flow through every other flow gap involved in heat exchange in different directions.

Single-Pass Or Multi-Pass PHE

Single-pass PHEs are normally used. In a single-pass PHE, all incoming and outgoing pipes are connected to the fixed plate, i.e. on the same side.

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

Path of flow media in a single-pass PHE

Small temperature differences between the flow media may call for multi- pass PHE. In this case, the connecting piping is on the fixed and on the loose plate, i.e. on both sides.

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

Path of flow media in a multi-pass PHE


NT50M Model Plate Heat Exchanger Specification

Surface Area 0.18㎡
Plate Theta Angle 129 ° 127°
Connection Diameter 56 mm
Plate Corrugate Thickness 2.8 mm
Plate Centre Length* Width 743*130 mm
Plate Shape Length*Width 864*246 mm

NT50M Plate Heat Exchanger Technical Information

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

Model Connection Size Dim. A Dim.B Dim.C
NT50T 2" nominal (DN50) 12.7" (323mm) 26.6" (675mm) Up to 44" (1120mm)
NT50M 40.4" (1025mm)
NT50X 54.9" (1395mm)

Heat Transfer Plate 316L Stainless,304 Stainless, Titanium, Hastelloy, 904L, SMO254 and others on request
Gasket

NBR, EPDM, Viton and others on request

Pressure Plate Carbon Steel, Stainless Steel and others on request
Port Connection Unlined, Metal Lined (Stainless, Titanium and others on request), Welded Neck Flange, threaded nipple and others on request
Maximum Design Pressure Maximum design pressure is 300 psig(21 bar). Depending on application.
Maximum Design Temperature Maximum standard design temperature is 330 °F (170 °C).Higher temperatures are available on request.
Approximate Maximum Liquid Flow Rate

NT50:175 gpm (40 m³/hour)

NT100: 830 gpm (190 m³/hour)

NT150:1540 gpm (350 m³/hour)

NT250:3960 gpm (900 m³/hour)

NT350:8380 gpm (1900 m³/hour)

NT500:20,000 gpm (4000 m³/hour)

The HE plate pack consists of individual embossed HE plates with the asso- ciated HE plate gaskets.
The HE plate gaskets seal the flow media towards one another and the envi- ronment.
The number and the arrangement of HE plates depends on the requirements specified in the order.

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

No. Component No. Component
11 WT plate profile 13 Leakage spaces
12 HE plate gasket 14 Round gasket sections

NT50M Plate Heat Exchanger Gasket & Plate Pictures

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

NT50M Plate Heat Exchangers Application And Benefits

Application:

With M&C Heat Parts product group, the NT series is a gasketed plate heat exchanger for multiple applications. Variety of materials that work across a broad range of liquids, temperatures and pressures. Well-suited for these liquid-to-liquid applications:

HVAC Chemical Sugar Marine
Food Renewable Energy Power

Benefits:

Versatility-

  • The right design, not a "good enough" design. A wide variety of materials, sizes, and plate configurations combine with sophisticated selection software to ensure a perfect selection, whatever your needs.
  • The compact footprint allows you to use it in locations that you wouldn't dream of with a shell and tube heat exchanger.

Higher Performance at a Lower Cost -

  • Optiwave plate corrugations distribute the liquid evenly across the entire plate width, maximizing heat transfer and minimizing the number of plates (and cost) required.

Convenient Maintenance-

  • PosLoc plate lead-ins cause the plate pack to self-align when re-installing.
  • Ecoloc tools-free gaskets make gasket replacement a snap.
  • Individual plates mean no heavy lifting tools are needed. Faster more efficient maintenance, with shorter down times.

Long Service Life-

  • Careful corrugation design provides the ideal balance of high turbulence and proper fluid distribution, reducing fouling from less than perfect media.

Plate Heat Exchanger Leak Conditions And Solutions

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

When the HE plate pack is tensioned to less than tensioning dimension a min., the HE plates are damaged. The PHE may become leaky and flow media can escape.

  • Never tension to less than tensioning dimension a min.
  • Ensure that the tensioning dimension a of the HE plate pack is always within the permitted value range a min. ≤ a ≤ a max.

Environmental damage due to leaks

  • When using environmentally hazardous media, ensure that these can be reliably collected in case of a PHE leak (e.g. collecting trays and suction equipment) and cannot pollute the environment

Damage to PHE by sudden pressure rise (liquid hammer ) or sudden pressure drop (cavitation hammer)

When the flow velocity of a flow medium changes, a liquid hammer or a cavitation hammer may occur. This can damage the PHE and flow media can escape.

  • Always open or close the valves of the piping connected to the PHE slowly.
  • Avoid sudden condensation of gases by suitable process control.

Damage to PHE due to freezing of flow media

  • Ensure that under all setting-up and operating conditions, the temperature never falls below the freezing temperature of the flow media used.

Leaks when putting multi-stage PHE into and out of operation

When putting multi-stage PHEs into and out of operation and failing to pressurize or relieve all sections evenly, the tensioning dimension may be exceeded in individual sections. This may produce leaks.

  • Ensure that when putting multi-stage PHEs into and out of operation, all sections must be pressurized or relieved evenly.

Plate Heat Exchanger Pictures

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

M&C Heat Parts Company Profile

M&C Heat Parts Co., Ltd is founded in Wuxi, Jiangsu. M&C is specialized in designing and manufacturing high quality heat transfer equipment. The range of products comprises plates & gaskets, plate heat exchangers, gasketed heat exchangers and brazed heat exchangers. Thus, as one of the few producers worldwide, M&C offers solutions with optimum thermodynamic designs for different industries and virtually all applications.

M&C provide you with one-stop accessories service, multuple-brand & multiple model alternatives for your choice. We'll meet all your requirements of plate heat exchanger and keep your machine running contunously through our rich storage and quick response.

Moreover, we have a strict quality control and after-sales service system, from material purchasing to finished product package until the product received in good condition. Our products have been widely used all over the world in various fields.

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

M&C Plate Heat Exchanger Plates & Gaskets Other Models Recommend

Sondex/Danfoss - S4A, S7, S20, S21, S22, S41, S43, S47, S65, S81, S86, S100, S120, S130, SFD7, SFD13, SW19 and so on;

APV/SPX - H17, N25, N35, A055, A085, J060, J092, J107, M92, M107, K55, K71, B110, B134, P105, P190, SR1, SR2, TR9GN, TR9AL and so on;

Tranter/Swep - GX12, GL13, GC26, GC51, GX26, GX51, GX42, GX64, GX85, GX91, GX140, GX145 and so on;

API/Schmidt - Sigma 7, Sigma 9, Sigma 13, Sigma 26, Sigma 27, Sigma 36, Sigma 66, Sigma 106, Sigma 229, Sigma Star 45, Sigma Star 90 and so on;

Vicarb - V4, V13, V20, V28, V45, V60, V100, V110, V130 and so on;

Hisaka - EX11, EX15, EX15, LX026, LX195, LX395, LX595, RX135, RX395, RX595, UX115, UX225, UX395, UX495, UX815, UX995 and so on;

GEA - VT04, VT10, VT20, VT40, VT80, VT405, VT805, VT1306, NT50M, NT50X, NT100S, NT150S, NT150L, NT250M, NT250L and so on;

Funke - FP04, FP05, FP14, FP16, FP08, FP22, FP31, FP40, FP41, FP70, FP100, FP120 and so on;

Thermowave - TL200SS/PP, TL250SS/PP, TL400SS/PP. TL650SS/PP and so on;

DHP - DX143, DX146, DX20V, DX20DL, DX20DM, DX30S, DX36M and so on;

LHE - HT101, HT102, HT104, HT151, HT152, HT202, HT232, HT233 and so on;

M&C Plate Heat Exchanger Goods ready to Delivery

NT50M AISI316L 0.5mm NBR Rubber Gaskets For GEA Heat Exchanger

Inquiry Cart 0